CUSTOM CAPABILITIES
PAST WORK
JOB PORTFOLIOS
BetaGuard PM 3.0™
The Superior Source Particulate Monitor
Engineered for improved performance, the new BetaGuard PM 3.0™ represents the latest advancement in system design. New advanced hardware features and completely redesigned system control software are based on over two million operating hours and over 10 years’ experience continuously monitoring particulate emissions from a variety of plant stacks across the country.
More alarm points are now watched. Daily calibrations of the mass and flow measurement are now faster leading to more data availability. ACA and SVA results are stored in the PLC memory for electronic retrieval. The faster processor in the ControlLogix PLC has increased the accuracy and repeatability of all timing sequences within the monitor’s operating system leading to more stable beta attenuation measurements. The new PLC and system program increases the monitor’s accuracy, reliability, and operability.
Teflon coated nozzles and a Teflon coated sample cone are new features. The Teflon coated nozzle reduces particulate deposition and loss in the sample probe. Field trials demonstrated much less scaling of particulate on the interior walls of the nozzle. The Teflon coated sample cone eliminates buildup of the filter paper on the ring forming the seal to the filter. Both hardware features have reduced maintenance.
The new BetaGuard PM 3.0 provides what you are looking for in a superior source particulate monitor.
PAST WORK JOB PORTFOLIOS
- MATS Hg, HCL, and PM CEMS Project
- Capital Recovery on Existing Continuous Emmissions Monitoring System
- Installation of Process Monitoring Systems
- Installation of Multiple Particulate Monitors at a Single Coal-Fired Power Plant
- Full Service Project Installation of BetaGuard Particulate Monitors for a Utility Plant
- Full Service Project Installation of BetaGuard Particulate Monitors for a Utility Plant
- Installation of a BetaGuard Particulate Monitor at a Wood-Fired Steam Generating Boiler
BETAGUARD PARTICULATE MONITOR (PM) CAPABILITIES
Particulate Conc. Range (selectable)
Dual Range Capable (selectable) |
0 – 1000 mg/m3
0 – 5 to 0 – 1000 |
Diluted Sample Flow Range | 2.5 – 3.5 m3/hr |
Minimum Batch Sampling Time | 140 seconds |
Minimum Cycle Time | 288 seconds |
Warm-up Time | 120 minutes |
Measurement Sources (2) | Carbon-14 |
Measurement Detectors (2) | Alpha-Beta-Gamma Detector
Geiger-Mueller (G-M) Tube |
Particulate Filter Medium | Glass Fiber Mat |
Power Requirements Instrument
Instrument (Optional) Heated Umbilical |
Single Feed-120 V AC, 30 A max
Dual Feed-UPS 120 V AC, 10 A and Non-UPS 120V AC, 20A Non-UPS 120V AC, 30 A max |
Instrument Air Requirement
Continuous Intermittent |
90 psig and -20°F Dewpoint
2 – 3 scfm sampling 6 – 10 scfm pulsed blowback |
Dimensions | 72″h x 30″w x 14″d |
Weight | 400 pounds |
Environmental Rating | NEMA 12 |
Operating Temperature | 50° – 120°F / 10° – 50°C |
Storage Temperature | 32° – 135°F / 0° – 60°C |
Dilution Probe Length
Weight Mounting Flange Material of Construction Maximum Flue Gas Temp. Isokinetic Control Range |
2 – 15 feet
35 – 90 pounds 6″ or 8″ ANSI Class 150 – 2-holed Hastelloy C276 Protection Pipe 750°F 10 – 110 ft/s Gas Velocity |
Sample Line Length | Up to 150 feet |
System Controller | A-B ControlLogix PLC |
Interface – Local and Remote | PanelView Plus 700 Touchscreen Display |
Interface – External | A-B FactoryTalk ViewPoint |
I/O Options | Point I/O (Cat6 cable or Fiber Optic)
RTU/ASCII Serial Modbus TCP/IP Network Modbus Other Networks Available |
Minimum Detection Limit | 0.5 mg/m3 at PS-11 15 minute cycle time
0.25 mg/m3 at 30 minute cycle time 0.125 mg/m3 at 60 minute cycle time |
Accuracy | <2% full scale |